MATERIAL DATA · COLD FORMING

SAE/AISI 1033(IFI-1033) CHQ wire

SAE/AISI 1033 (IFI-1033) Cold Heading Wire technical data, compliant with ASTM F2282. View the chemical composition, mechanical properties, and related technical requirements for the current grade.

SAE/AISI 1033(IFI-1033) CHQ wire product image
SAE/AISI 1033(IFI-1033) · Cold heading wire
01StandardASTM F2282
02GradeSAE/AISI 1033(IFI-1033)
03Product formCold heading wire
04Delivery noteConfirmed by order specification

Material technical data

Only data directly related to this material is shown here. Inspection, equipment, process and packaging information is linked separately.

1. Chemical Composition

Chemical composition ranges and limits for carbon steel (mass fraction, %)

Delivery ConditionIFI Steel GradeC Lower LimitC Upper LimitMn Lower LimitMn upper limitP upper limitS upper limitSi requirements
AlKIFI-10330.310.360.700.900.0200.020See silicon content requirements

Abbreviations: AlK = aluminum-killed; R = rimmed steel; SiFg = silicon-killed fine-grain; SiCg = silicon-killed coarse-grain; CgP = coarse-grain practice. The "B" in boron steel grades indicates boron-added steel; boron and titanium content requirements shall comply with ASTM F2282.

Permissible deviations for product analysis (%)

ElementSpecified range or upper limitPermissible deviation (above upper limit or below lower limit)
C≤ 0.250.02
C> 0.25 and ≤ 0.550.03
Mn≤ 0.900.03
Mn> 0.90 and ≤ 1.650.06
PExceeding the upper limit is permitted only0.008
SExceeding the upper limit is permitted only0.008
Si≤ 0.300.02
CuExceeding the upper limit is permitted only0.03
SnExceeding the upper limit is permitted only0.01
NiExceeding the upper limit is permitted only0.03
CrExceeding the upper limit is permitted only0.03
MoExceeding the upper limit is permitted only0.01
VExceeding the upper limit is permitted only0.01
BNot applicable unless misapplication is indicated

Silicon content requirement (mass fraction, %)

IFI Steel GradeSiFg lower limitSiFg upper limitSiCg/CgP lower limitSiCg/CgP upper limitAlK upper limitR upper limit
IFI-10330.150.300.150.300.10Not applicable

2. Mechanical Properties

Grade: IFI-1033. The listed tensile strength is the maximum value, and the reduction of area is the minimum value.

Material ConditionMaximum Tensile Strength (ksi)Minimum Reduction of Area (%)
Wire Rod/Bar - Annealed8058
Wire Rod/Bar - Spheroidizing Annealed7460
Steel Wire - Spheroidizing Annealed to Finished Size (SAFS)7264
Steel Wire - Intermediate Annealed Process (AIP)8956
Steel Wire – Intermediate Spheroidizing Annealing (SAIP)8258

Note A: For aluminum-killed steel, reduce the maximum tensile strength by 3 ksi and increase the minimum reduction of area by 1 percentage point; for rimmed steel, reduce by 5 ksi and increase by 2 percentage points, respectively. For AIP and SAIP wire with a diameter less than 0.200 in., increase the maximum tensile strength by 50 psi for each 0.001 in. decrease in diameter. The reduction of area test does not apply to wire with a diameter less than 0.092 in.

3. Microstructure and Spheroidization Requirements

The minimum rating for spheroidizing annealed material is G2 or L2; the optimal spheroidization rate shall be no less than 90%. The austenitic grain size of fine-grain steel and the testing method shall comply with the relevant provisions of ASTM F2282.

4. Decarburized Layer Limits

Applicable to killed steel with a carbon content exceeding 0.15%; limits are determined based on the nominal diameter of the specimen.

Nominal Diameter (in.)Maximum Depth of Free Ferrite Layer (in.)Maximum Total Average Affected Depth (TAAD) (in.)Maximum Depth at Most Unfavorable Location (in.)
≤ 25/640.0010.0050.008
> 25/64 and ≤ 5/80.0010.0060.009
> 5/8 and ≤ 55/640.0010.0070.011
> 55/64 and ≤ 10.0010.0080.012
> 1 and ≤ 1-1/20.0010.0100.015

5. Surface Quality and Coating

The oxide scale on hot-rolled material shall be removable by pickling or mechanical descaling. The surfaces of wire rod, bars, and steel wire shall be free from defects that impair usability, such as folds, holes, pitting, scratches, and laps. The type and requirements of the coating shall be determined by the purchaser based on the cold-forming process and the technical agreement of the order.

Application and ordering note

Chemical composition, mechanical properties, tolerances and delivery condition must be confirmed against the applicable standard edition, customer drawing and order specification.

Send a technical enquiry

Contact technical team →
Technical enquiry